SN:2000mm Digital ultrasonic sensor

The principle of ultrasonic distance measurement is to emit sound waves through an ultrasonic transmitter, and when the sound waves encounter obstacles, they return. The distance between the transmitter and the obstacle is calculated based on the conduction velocity and return time of the sound waves. This is the time difference distance measurement method. Ultrasonic waves are also a type of sound wave, and their propagation speed is related to factors such as temperature and pressure, but the influence of temperature can be ignored when the temperature changes little. If there is a high requirement for distance measurement, temperature compensation should be used for calibration
  • Overview
  • Related Products
Product modelUBX200-GM30-V4-H5UBX400-GM30-V4-H5UBX600-GM30-V4-H5UBX800-GM30-V4-H5
UBX200-GM30-V5-H5UBX400-GM30-V5-H5UBX600-GM30-V5-H5UBX800-GM30-V5-H5
UBX200-GM30-V6-H5UBX400-GM30-V6-H5UBX600-GM30-V6-H5UBX800-GM30-V6-H5
UBX200-GM30-V7-H5UBX400-GM30-V7-H5UBX600-GM30-V7-H5UBX800-GM30-V7-H5
UBX200-GM30-VI-H5UBX400-GM30-VI-H5UBX600-GM30-VI-H5UBX800-GM30-VI-H5
UBX200-GM30-VU-H5UBX400-GM30-VU-H5UBX600-GM30-VU-H5UBX800-GM30-VU-H5
Detection
range
 80 ... 2000 mm200 ... 4000 mm350 ... 6000 mm400 ... 8000 mm
Non-detection
zone
 0 ... 80 mm0 ... 200 mm0 ... 350 mm0 ... 400 mm
Transducer
frequency
 approx. 180 kHzapprox. 85 kHzAbout 65KHzAbout 65KHz
response timeAbout 195 ms145 ms minimum
440 ms factory setting
285 ms minimum
850 ms factory setting
285 ms minimum
850 ms factory setting
Standard target versionmax. 30 Hzmax. 13 Hzmax. 7 Hzmax. 7 Hz
type of outputV4 :NPN normally open/normally closed   V6:2 switch outputs PNP, NO/NC,                 VI:4-20mA
V5:PNP normally open/normally closed   V7:2 switch outputs NPN, NO/NC,               VU:0-10V
working
voltage
10-30V DC ripple 10%
Rated working
current
200mA Passage/overload protection2 x 100 mA , short-
circuit/overload protected
Repetition
accuracy of
≤ 0.5%≤ 0.1%
Range
adjustment
Adjust the farthest and nearest range through the adjusting line
Degree of
protection
IP65
Connection modeConnector plug M12 x 1 , 5-pin/2m PVC cable
LED yellow lightThe yellow light of the switch status indicator flashes. The target is detected under the set status
LED red lightThe red light is always on: error
Red light flashing: no target is detected in the set state