BPE series DC power type, Solid state output type

Sensitivity adjusterTimer function: ON Delay, OFF Delay, One-shot DelayNPN/PNP open collector output (Dc power type)Self-diagnosis function (green LED turns on in stable level)Wide power supply range: Universal 24-240VDC/24-240VACProtection structure lP66 (lEC standard)
  • Overview
  • Related Products
Model Standard type BPE-QL15M BPE-KL5M BPE-EL3M BPE-CL70
With Timer BPE-QL15M-T BPE-KL5M-T BPE-EL3M-T BPE-CL70-T
Sensing type Through-beam Retro-Reflection Retro-Reflection
(with polarizing filter)
Diffuse Reflection
Sensing Range 15M 5M 3M 700mm
Sensin target Opaque materials of
Min.Φ15mm
Opaque materials of Min.Φ60mm Transparent,
Opaque materials
Hysteresis ----------------- Max.20% at rated
setting distance
Response time Max.1ms
Power supply 12 - 24 VDC ± 10 % (Ripple P-P:Max.10%)
Current consumption Max.50mA
Light source Infrared LED(850nm) Red LED(660nm) Infrared LED(940nm)
Sensitivity adjustment Sensitivity adjuster
Operation mode Light ON/Dark ON operation mode switch
Control output NPN or PNP open collector output
Load voltage: max. 30VDC Load current: max.200mA
Residual voltage - NPN:max.1VDC PNP: max.2.5VDC
Self-diagnosis output NPN open collector output
(green LED turns on at stable operation and output (transistor output) turns on)
Load voltage: max.30VDC  Load current: max.50mA
Residual voltage -max.1VDC(50mA) max. 0.4VDC(16mA)
Protection circuit Reverse polarity protection circuit, output short overcurrent protection circuit
Timer function Selectable ON delay, OFF delay, one shot delay by slide switch
[delay time: 0.1 to 5 sec (timer adjuster)]
Indicator Operation indicator: yellowLED, self-diagnosis indicator: green LED
Connection Terminal connection
Insulation resistance Min.20MΩ (at 500VDC mega )
Insulation type Double or strong insulation(dielectric voltage between
the measured input and the power : 1.5 kV)
Noise strength ±240V the square wave noise (pulse width:1)by the noise simulator
Dielectric strength 1500VAC 50/60Hz for 1minute
Vibration Mechanical 1.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y,2 directions for 2 hours
Malfunction 1.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y,2 directions for 10 minutes
Shock Mechanical 500 m/s2(50G)in X,Y,Z directions for 3 times
Malfunction 100 m/s2(10G)in X,Y,Z directions for 3 times
Environ-
ment
Ambient illu. Sunlight :Max.11,000lx , Incandescent lamp:Max.3,000lx (receiver illumination)
Ambient temp. -20~+65℃ C27(at non-freezing status),Storage:-25~+70℃
Ambient humi. 35~85%RH, Storage:35~85%RH
Material Case, lens cover: polycarbonate,
sensing part: acrylic, bracket, bolt, nut: steel chromium molybdenum
Protection IP66(IEC standard)