- Overview
- Related Products
Sensing method | Diffuse-reflective | |||
Model | NPN output |
BPL-CC10 | BPL-CC50 | BPL-CC1M |
PNP output |
BPL-CF10 | BPL-CF50 | BPL-CF1M | |
Sensing distance | 100mm | 500mm | 1M | |
Spot diameter (reference value) | 40 × 45 mm Sensing distance of 100 mm |
40 × 50 mm Sensing distance of 300 mm |
120 × 150 mm Sensing distance of 1 m |
|
Standard sensing object | -------- | |||
Differential travel | 20% max. | |||
Directional angle | -------- | |||
Light source (wavelength) | Infrared LED (850 nm) | |||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | |||
Current consumption | 25 mA max. | |||
Control output | NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
|||
Operation mode | Light-ON/Dark-ON selectable by wiring | |||
Indicator | Operation indicator (orange) Stability indicator (green) |
|||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection |
|||
Response time | 0.5 ms | |||
Sensitivity adjustment | One-turn adjuster | |||
Ambient illumination (Receiver side) | Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max. | |||
Ambient temperature range | Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation) | |||
Insulation resistance | 20 MΩ min. at 500 VDC | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | |||
Degree of protection | IP67 | |||
Material | Case | ABS | ||
Lens and Display | PMMA | |||
Adjuster | POM | |||
Nut | POM |