F36 series ultrasonic sensor
Distance measuring sensors are different from ordinary proximity switches and photoelectric sensors. Compared to inductive or capacitive proximity switches, distance sensors have a longer detection distance and can achieve detection over longer distances. Compared with photoelectric sensors, distance sensors can be applied in more harsh environments and are not affected by the color of the target object or factors such as dust and water mist in the air
- Overview
- Related Products
Product model | UCX50-F36-D4-H4 | UCX100-F36-D4-H4 | UCX200-F36-D4-H4 | ||
UCX50-F36-D5-H4 | UCX100-F36-D5-H4 | UCX200-F36-D4-H4 | |||
Detection range | 50..500mm | 70..1000mm | 80...2000mm | ||
Non-detection zone | 0...50mm | 0...70mm | 0mm ..80mm | ||
Transducer frequency | About 380KHz | About 205KHz | 180KHZ | ||
response time | 50ms | About 125ms | About 150ms | ||
Standard target version | ≤10Hz | ≤ 3Hz | ≤ 3.3Hz | ||
type of output | D4 :NPN normally open/normally closed | ||||
D5:PNP normally open/normally closed | |||||
Rated working current | 200mA Passage/overload protection | ||||
accuracy of rated working | ≤ 0.5% | ||||
working voltage | 10-30V DC ripple 10% | ||||
Range adjustment | Adjust the farthest and nearest range through the adjusting line | ||||
Degree of protection | IP65 | ||||
Connection mode | Connector plug M12 x 1 ,4-pin/2m PVC cable | ||||
LED yellow light | The yellow light of the switch status indicator flashes. The target is detected under the set status | ||||
LED red light | The red light is always on: error Red light flashing: no target is detected in the set state |