F42 2m ultrasonic sensor
Due to the advantages of easy directional emission, good directionality, easy intensity control, and no direct contact with the measured object, ultrasound is widely used in liquid level measurement. In measurement, pulsed ultrasonic waves are emitted by sensors (transducers), and the sound waves are reflected by the surface of the object and received by the same sensor, which converts them into electrical signals. And the distance between the sensor and the object being measured is calculated based on the time between the emission and reception of sound waves
- Overview
- Related Products
Product model | UCX50-F42-DI-H5 | UCX200-F42-DI-H5 | UCX400-F42-DI-H5 | ||
UCX50-F42-DU-H5 | UCX200-F42-DU-H5 | ||||
UCX50-F42S-DI-H5 | UCX200-F42S-DI-H5 | UCX400-F42-DU-H5 | |||
UCX50-F42S-DU-H5 | UCX200-F42S-DU-H5 | ||||
Detection range | 50..500mm | 80..2000mm | 200...4000mm | ||
Non-detection zone | 0...50mm | 0...80mm | 0mm ..200mm | ||
Transducer frequency | About 380KHz | About 180KHz | 85KHZ | ||
response time | 21ms | About 65ms | About 145ms | ||
Standard target version | 100mm*100mm | ||||
type of output | DI :Passage/overload protection | ||||
DU:0-10V/0-5V | |||||
Rated working current | 200mA Passage/overload protection | ||||
accuracy of rated working | ≤ 0.5% | ||||
working voltage | 10-30V DC ripple 10% | ||||
Range adjustment | Adjust the farthest and nearest range through the adjusting line | ||||
Degree of protection | IP65 | ||||
Connection mode | Connector plug M12 x 1 , 5-pin/2m PVC cable | ||||
LED yellow light | The yellow light of the switch status indicator flashes. The target is detected under the set status | ||||
LED red light | The red light is always on: error Red light flashing: no target is detected in the set state |