L2 ultrasonic bin level sensor Sn:4000mm 4-20mA/0-10V
The diameter of the coil or coil can be monitored in real time through an analog output ultrasonic sensor, and the driving system adjusts or stops based on the analog signal value. For very small diameter measurements
- Overview
- Related Products
Product model | UCX50-L2-DI-H5 | UCX200-L2-DI-H5 | UCX400-L2-DI-H5 | ||
UCX50-L2-DU-H5 | UCX200-L2-DU-H5 | UCX400-L2-DU-H5 | |||
Detection range | 50..500mm | 80..2000mm | 200...4000mm | ||
Non-detection zone | 0...50mm | 0...80mm | 0mm ..200mm | ||
Transducer frequency | About 380KHz | About 180KHz | 85KHZ | ||
response time | 21ms | About 65ms | About 145ms | ||
Standard target version | 100mm*100mm | ||||
type of output | DI :Passage/overload protection | ||||
DU:0-10V/0-5V | |||||
Rated working current | 200mA Passage/overload protection | ||||
accuracy of rated working | ≤ 0.5% | ||||
working voltage | 10-30V DC ripple 10% | ||||
Range adjustment | Adjust the farthest and nearest range through the adjusting line | ||||
Degree of protection | IP65 | ||||
Connection mode | Connector plug M12 x 1 , 5-pin/2m PVC cable | ||||
LED yellow light | The yellow light of the switch status indicator flashes. The target is detected under the set status | ||||
LED red light | The red light is always on: error Red light flashing: no target is detected in the set state |