When it comes to detecting the presence of personnel, we will recommend choosing a sensor with a detection distance that exceeds the actual required detection distance. The farther the detection distance of the sensor, the lower the frequency of ultrasonic waves. The lower the frequency of ultrasound, the easier it is to detect clothing fabrics that absorb waves, such as wool and corduroy.
- Overview
- Related Products
Product model | UBX30-GM1840-D4-H4 | UBX80-GM1840-D4-H4 | UBX30-GM1840-DI-H4 | UBX80-GM1840-DI-H4 | |
UBX30-GM1840-D5-H4 | UBX80-GM1840-D5-H4 | UBX30-GM1840-DU-H4 | UBX80-GM1840-DU-H4 | ||
Detection range | 50…300mm | 50…800mm | 50…300mm | 50…800mm | |
Non-detection zone | 0mm ..50mm | 0mm ..50mm | 0mm ..50mm | 0mm ..50mm | |
Transducer frequency | About 390KHz | About 225KHZ | About 390KHz | About 225KHZ | |
response time | About 50ms | About 100ms | About 50ms | About 100ms | |
Standard target version | ≤ 13Hz | ≤ 4Hz | 100mm*100mm | 100mm*100mm | |
type of output | D4 :NPN normally open/normally closed DI:4…20mA | ||||
D5:PNP normally open/normally closed DU:0-10V | |||||
working voltage | 10-30V DC ripple 10% | ||||
Rated working current | 200mA Passage/overload protection | ||||
accuracy of rated working | ≤ 1% | ±0.5%of full-scale value | |||
Range adjustment | Adjust the farthest and nearest range through the adjusting line | ||||
Degree of protection | IP65 | ||||
Connection mode | Connector plug M12 x 2 , 4-pin/2m PVC cable | ||||
LED yellow light | The yellow light of the switch status indicator flashes. The target is detected under the set status |
||||
LED red light | The red light is always on: error Red light flashing: no target is detected in the set state |