profile data | M30*1mm |
Installation method | Flushed |
Reliable detection distance | 0-7.6mm |
DC 3-wire | NPN | NO | BCLT8-GM30-N1-C |
NC | BCLT8-GM30-N2-C |
PNP | NO | BCLT8-GM30-P1-C |
NC | BCLT8-GM30-P2-C |
DC 2 wire | NO | BCLT8-GM30-D1-C |
NC | BCLT8-GM30-D2-C |
AC 2-wire | NO | BCLT8-GM30-A1-C |
NC | BCLT8-GM30-A2-C |
Housing | Threaded type |
Operating voltage [V] | 20...250 AC/DC |
Reverse polarity protection | no |
Max. voltage drop switching output DC [V] | 8 |
Max. voltage drop switching output AC [V] | 10 |
Minimum load current [mA] | 5 |
Max. leakage current [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA] | 200; (for UL Application: 200 / 100 DC) |
Permanent current rating of switching output DC [mA] | 200; (for UL application: 200 AC / 100 DC) |
Short-time current rating of switching output [mA] | 1500; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] | 25 |
Switching frequency DC [Hz] | 40 |
Short-circuit proof | no |
Overload protection | no |
Sensing range adjustable | yes |
Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr] | 1...15 |
Switch-point drift | -15...15 |
Ambient temperature | -25...70 |
Protection | IP 65 |
Increased immunity | yes |
Housing | Threaded type |
Materia | housing: stainless steel |