rofile data | M34*1mm |
Installation method | Flushed |
Detection distance | 20mm |
Reliable detection distance | 0-16.2mm |
DC 3- wire聽 | NPN | NO | BCLN20-GS34-N1-C |
NC | BCLN20-GS34-N2-C |
PNP | NO | BCLN20-GS34-P1-C |
NC | BCLN20-GS34-P2-C |
DC 2 wire | NO | BCLN20-GS34-D1-C |
NC | BCLN20-GS34-D2-C |
AC 2-wire | NO | BCLN20-GS34-A1-C |
NC | BCLN20-GS34-A2-C |
Housing | tubular |
Operating voltage [V] | 10...36 DC |
Current consumption [mA] | 13; (24 V) |
Reverse polarity protection | yes |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 40 |
Short-circuit proof | yes |
Overload protection | yes |
Switch-point drift [% of Sr] | -15...15 |
Ambient temperature [C] | -25...70 |
Protection | IP 65 |
Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Material | PBT |
Hysteresis [% of Sr] | 1...15 |
Switch-point drift | -15...15 |
Ambient temperature [C] | -25...70 |
Protection | IP 65 |
Increased immunity | yes |
Housing | Threaded type |
Materia | PBT |