Installation method |
Flushed |
Detection distance |
20mm |
Reliable detection distance |
0...16,2mm |
DC 3- wire/DC 4-wire |
NPN |
NO |
NBB20-L2-E0-V1 |
NC |
NBB20-L2-E1-V1 |
NO+NC |
NBB20-L2-A0-V1 |
PNP |
NO |
NBB20-L2-E2-V1 |
NC |
NBN20-L2-E3-V1 |
|
NO+NC |
NBB20-L2-A2-V1 |
DC 2-wire |
NO |
NBB20-L2-Z0-V1 |
NC |
NBB20-L2-Z1-V1 |
AC 2-wire |
NO |
NBB20-L2-U0-V1 |
NC |
NBB20-L2-US-V1 |
Operating voltage |
10 ... 30 V DC |
Switching frequency |
0 ... 440 Hz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
pulsing |
Voltage drop |
≤ 2 V |
Operating current |
0 ... 200 mA |
Off-state current |
0 ... 0.5 mA |
No-load supply current |
≤ 20 mA |
Time delay before availability |
80 ms |
Operating voltage indicator |
LED, green |
Switching state indicator |
LED, yellow |
MTTFd |
1510 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0% |
Rated insulation voltage |
253 V |
Rated impulse withstand voltage |
4000 V |
Ambient temperature |
25 ... 85 °C |
Storage temperature |
-40 ... 85 °C |
Connection type |
Connector plug M12 x 1 , 4-pin/screw terminals |
Mass |
130 g |