Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

TL-N10M series

Detect metal objects at a distance of 10mm
  • Overview
  • Related Products
Installation method Flushed
Detection distance 10mm
Reliable detection distance 0...8mm
DC 3- wire NPN NO TL-N10ME1
NC TL-N10ME2
PNP NO TL-N10MF1
NC TL-N10MF2
DC 2-wire NO TL-N10MD1
NC TL-N10MD2
AC 2-wire NO TL-N10MY1
NC TL-N10MY2
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal
Standard sensing object Iron, 40 × 40 × 1 mm
Response frequency E/F Models: 500 Hz
Y Models: 10 Hz
Power supply voltage (operating voltage range) E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption E/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage current Y Models: Refer to Engineering Data on page 5
Control Load current E/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
output Y Models: 10 to 200 mA
Residual voltage E/F Models: 1 V max. (load current: 200 mA)
Y Models: Refer to Engineering Data on page 5. 
Indicators E/F Models: Detection indicator (red)
Operation mode E1/F1/Y1 Models: NO
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details. 
Protection circuits E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient temperature range Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence E/F Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance  Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 240 g

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000