Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

TL-N5M series

Detect metal objects at a distance of 5mm
  • Overview
  • Related Products
Installation methodFlushed
Detection distance5mm
Reliable detection distance0...4mm
DC 3- wireNPNNOTL-N5ME1
NCTL-N5ME2
PNPNOTL-N5MF1
NCTL-N5MF2
DC 2-wireNOTL-N5MD1
NCTL-N5MD2
AC 2-wireNOTL-N5MY1
NCTL-N5MY2
Differential travel15% max. of sensing distance
Detectable objectFerrous metal
Standard sensing objectIron, 30 × 30 × 1 mm 
Response frequencyE/F Models: 500 Hz
Y Models: 10 Hz
Power supply voltage (operating voltage range)E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumptionE/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage currentY Models: Refer to Engineering Data on page 5
Control
output
Load currentE/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
Residual voltageE/F Models: 1 V max. (load current: 200 mA)
Y Models: Refer to Engineering Data on page 5. 
IndicatorsE/F Models: Detection indicator (red)
Operation modeE1/F1/Y1 Models: NO
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details. 
Protection circuitsE Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient temperature rangeOperating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity rangeOperating/Storage: 35% to 95% (with no condensation)
Temperature influence±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influenceE/F Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation resistance50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strengthE/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Connection methodPre-wired Models (Standard cable length: 2 m)
Weight (packed state)Approx. 190 g

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000